دوره 21، شماره 84 - ( 1-1392 )                   جلد 21 شماره 84 صفحات 56-47 | برگشت به فهرست نسخه ها

XML English Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Ehyaei A, Heravian J, Esmaily H A. Evaluating the Changes in Distance Stereopsis Caused by Induced Heterophoria in Normal Persons by Three Needle Test. J Adv Med Biomed Res 2013; 21 (84) :47-56
URL: http://journal.zums.ac.ir/article-1-2071-fa.html
احیائی اکرم، هرویان جواد، اسماعیلی حبیب ا.... ارزیابی تغییرات دید عمق دور افراد نرمال در اثر هتروفوریای ایجاد شده به‌وسیله‌ی تست سه میله. Journal of Advances in Medical and Biomedical Research. 1392; 21 (84) :47-56

URL: http://journal.zums.ac.ir/article-1-2071-fa.html


1- ، ehyaeia881@mums.ac.ir
چکیده:   (155165 مشاهده)

Backgrounds and Objective: Stereoacuity is due to a relative difference between images because of retinal disparity. Measurment of stereoacuity is important for diagnosis and treatment of binocular anomalies and noerological problems. The aim of this study was to determine the effect of induced heterophoria by base-out and base-in prisms on distance stereopsis by the Three Needle Test. Materials and Methods: This descriptive-analytical study was performed on 50 normal persons in the Optometry Clinic at Mashhad University of Medical Sciences during 2012. After primary examination, distance heterophoria was determined by cover test and prism bar. All subjects were orthophoric and had a maximum corrected vision of 66. Esophoria and exophoria were induced using prisms dioptres of 2, 4, 6, and 8 base-in and base-out. The stereopsis was then determined by the Three Needle test in distance observation of 6 meters in orthophoric, esophoric, and exophoric states. Data were analyzed using SPSS software. Results: Comparison between mean stereopsis in orthophoric and induced esophoric states was only statistically significant in 4 prism dioptres (P=0.006). However, comparison of mean stereopsis in orthophoric with induced exophoric states indicated statistically significant differences for all values of 2, 4, 6, and 8 prism dioptres (P=0.009, P<0.0001, P<0.0001and P<0.0001 respectively). Comparison between the mean stereopsis for the induced esophoric and exophoric states indicated statistically significant differences for 2, 4, and 6 prism dioptres. Conclusion: There is a reduction of stereopsis with induced heterophoria. Stereopsis seems to decrease more with induced esophoria than exophoria.

متن کامل [PDF 214 kb]   (159213 دریافت)    
نوع مطالعه: کارآزمایی بالینی |
دریافت: 1391/12/3 | پذیرش: 1391/12/22 | انتشار: 1391/12/22

ارسال پیام به نویسنده مسئول


بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به Journal of Advances in Medical and Biomedical Research می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2025 CC BY-NC 4.0 | Journal of Advances in Medical and Biomedical Research

Designed & Developed by : Yektaweb