دوره 17، شماره 68 - ( 7-1388 )                   جلد 17 شماره 68 صفحات 20-9 | برگشت به فهرست نسخه ها

XML English Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Golami M, Mohammadi H, Mokhtari S A. Application of Reverse Osmosis Technology for Arsenic Removal from Drinking Water. J Adv Med Biomed Res 2009; 17 (68) :9-20
URL: http://journal.zums.ac.ir/article-1-987-fa.html
غلامی میترا، محمدی حامد، مختاری سید احمد. حذف آرسنیک از آب آشامیدنی با استفاده از فن‌آوری اسمز معکوس. Journal of Advances in Medical and Biomedical Research. 1388; 17 (68) :9-20

URL: http://journal.zums.ac.ir/article-1-987-fa.html


1- ، GolamiM@Iums.ac.ir
چکیده:   (168736 مشاهده)

Background and Objective: Arsenic (As) is a highly toxic metalloid found in ground and surface waters. Arsenic contamination in drinking water leads to harmful effects on human health. In this study, the efficacy of Reverse Osmosis (RO) membrane technology was evaluated for arsenic removal from drinking water. Materials and Methods: This experimental study was carried out on RO membrane spiral- wound module (model: 2521 TE, CSM Co. Korea) in pilot scale. After preparation of sodium arsenate solution in the laboratory, performance of RO membrane system in arsenic (As) removal was investigated. Experiments were conducted with five different pressures (100, 130, 160, 190, 210 Psi), pH (4, 5.5, 7, 8.5, 10), temperature (20, 25, 30, 35, 40°C) and an initial As concentration of 0.2 mg/L. The influence of different feed concentrations (0.2, 0.5, 1, 1.5, 2 mg/L) on As removal efficiency was also examined. In each step, flux was measured and after 30 minutes samples were taken. Arsenic amount in feed and permeate were measured by silver diethyldithiocarbamate (AgDDTC) method. Results: The results of this study demonstrated that greater than 90% of As can be eliminated from drinking water. Also the results showed that the pressure of 190 psi, As concentration of 0.2-0.5mg/L, temperature of 25-300C and pH = 6-8 were the optimal conditions. Conclusion: Arsenic removal efficiency in optimal conditions of system performance was up to 99%.

متن کامل [PDF 229 kb]   (160116 دریافت)    
نوع مطالعه: مقاله پژوهشی |
دریافت: 1388/9/10 | پذیرش: 1393/4/5 | انتشار: 1393/4/5

ارسال پیام به نویسنده مسئول


بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به Journal of Advances in Medical and Biomedical Research می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2025 CC BY-NC 4.0 | Journal of Advances in Medical and Biomedical Research

Designed & Developed by : Yektaweb