Volume 20, Issue 79 (5-2012)                   J Adv Med Biomed Res 2012, 20(79): 44-54 | Back to browse issues page

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Goshvarpour A, Rahati Ghoochani S, Goshvarpour A, Saadatian V. Estimating the Depth of Meditation Using Electroencephalogram and Heart Rate Signals. J Adv Med Biomed Res 2012; 20 (79) :44-54
URL: http://journal.zums.ac.ir/article-1-1755-en.html
1- Dept. of Biomedical Engineering, Islamic Azad University (IAU), Mashhad Branch, Mashhad, Iran
2- Dept. of Electrical Engineering, IAU, Mashhad Branch, Mashhad, Iran.
3- Dept. of Biomedical Engineering, Islamic Azad University (IAU), Mashhad Branch, Mashhad, Iran , ateke.goshvarpour@gmail.com
4- Faculty of Medicine, Dept. of Psychiatry, IAU, Mashhad Branch, Mashhad, Iran.
Abstract:   (166892 Views)

Background and Objective: Meditation is commonly perceived as an alternative medicine management tool for psychological diseases such as depression and anxiety disorders. To our knowledge, there is no published study providing an index for estimating meditation's depth from biological signals. Estimating the depth of meditation can be useful in controlling its different levels, and it can be used as a biofeedback technique to help a person achieve the desired state of meditation. In this study, an index for meditation depth is offered using the features of electroencephalogram and heart rate signals. Material and Methods: For this purpose, EEG signals in Fz, Cz, and Pz channels, and the heart rate time series of 25 healthy women were collected both before and during the meditations. The algorithm is suggested based on the rational alpha power of EEG signals and the time domain feature of the heart rate to estimate the depth of meditation. Results: The analysis of biological signals using this method suggests that 22 of the 25 participants have experienced the deepest meditation state. Interestingly, 2 of the beginners as well as one expert-mediators could not reach the deepest state by following up the master mediator. These results were in line with the evaluation of the questionnaire. Conclusions: The suggested algorithm has some practical characteristics including: the option of being calibrated for each subject not requiring high-volume calculations and it does not take much time.

Full-Text [PDF 249 kb]   (159676 Downloads)    
Type of Study: Clinical Trials |
Received: 2012/04/18 | Accepted: 2014/06/21 | Published: 2014/06/21

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2025 CC BY-NC 4.0 | Journal of Advances in Medical and Biomedical Research

Designed & Developed by : Yektaweb