Volume 21, Issue 84 (3-2013)                   J Adv Med Biomed Res 2013, 21(84): 47-56 | Back to browse issues page

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Ehyaei A, Heravian J, Esmaily H A. Evaluating the Changes in Distance Stereopsis Caused by Induced Heterophoria in Normal Persons by Three Needle Test. J Adv Med Biomed Res 2013; 21 (84) :47-56
URL: http://journal.zums.ac.ir/article-1-2071-en.html
1- Dept. of Optometry, School of Para Medicine, Mashhad University of Medical Sciences, Mashhad, Iran , ehyaeia881@mums.ac.ir
2- Dept. of Optometry, School of Para Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
3- Dept. of Social Medicine, School of Health, Mashhad University of Medical Sciences, Mashhad, Iran
Abstract:   (155202 Views)

Backgrounds and Objective: Stereoacuity is due to a relative difference between images because of retinal disparity. Measurment of stereoacuity is important for diagnosis and treatment of binocular anomalies and noerological problems. The aim of this study was to determine the effect of induced heterophoria by base-out and base-in prisms on distance stereopsis by the Three Needle Test. Materials and Methods: This descriptive-analytical study was performed on 50 normal persons in the Optometry Clinic at Mashhad University of Medical Sciences during 2012. After primary examination, distance heterophoria was determined by cover test and prism bar. All subjects were orthophoric and had a maximum corrected vision of 66. Esophoria and exophoria were induced using prisms dioptres of 2, 4, 6, and 8 base-in and base-out. The stereopsis was then determined by the Three Needle test in distance observation of 6 meters in orthophoric, esophoric, and exophoric states. Data were analyzed using SPSS software. Results: Comparison between mean stereopsis in orthophoric and induced esophoric states was only statistically significant in 4 prism dioptres (P=0.006). However, comparison of mean stereopsis in orthophoric with induced exophoric states indicated statistically significant differences for all values of 2, 4, 6, and 8 prism dioptres (P=0.009, P<0.0001, P<0.0001and P<0.0001 respectively). Comparison between the mean stereopsis for the induced esophoric and exophoric states indicated statistically significant differences for 2, 4, and 6 prism dioptres. Conclusion: There is a reduction of stereopsis with induced heterophoria. Stereopsis seems to decrease more with induced esophoria than exophoria.

Full-Text [PDF 214 kb]   (159232 Downloads)    
Type of Study: Clinical Trials |
Received: 2013/02/21 | Accepted: 2013/03/12 | Published: 2013/03/12

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.